Product Data
MODEL 213R
LEGACYt--RNC SERIES HEA T PUMP
SIZES 018 TO 060
1--1/2 TO 5 NOMINAL TONS
Shown with optional dense coil guard
FEATURES / BENEFITS
Efficiency
S
13 SEER/ 11 EER / Up to 8.6 HSPF (Nominal)
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S
Sound level as low as 75 dBA
Comfort
S
System supports Thermidistatt or standard thermostat
controls
Reliability
S
Front--seating service valves
S Scroll compressor
S Filter drier
S Loss of charge pressure switch
S Balanced refrigeration system for maximum reliability
Durability
DuraGuardt protection package:
S Solid, Durable sheet metal construction
S Wire coil guard
S Baked--on, complete coverage, powder paint
Applications
S
Long-- line -- up to 250 feet total equivalent length, up
to 200 feet condenser above evaporator, or up to 80 ft.
evaporator above condenser (See Longline Guide for
more information.)
S Low ambient (down to --20_F) with accessory kit
Warranty
Single Phase
S 5 year limited compressor warranty
S 5 year limited parts warranty
Three Phase
S 5 year limited compressor warranty
S 1 year limited parts warranty
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - Product Data

Product DataMODEL 213RLEGACYt--RNC SERIES HEA T PUMPSIZES 018 TO 0601--1/2 TO 5 NOMINAL TONSShown with optional dense coil guardFEATURES / BENEFITSEff

Page 2 - STANDARD FEATURES

10COMBINATION RATINGSUnit Size--- S e r i e sIndoor ModelCoolingCapacityARI Standard RatingsCooling HeatingFurnace ModelFactoryEnhanceStandardRatingSE

Page 3 - PHYSICAL DATA

11COMBINATION RATINGS -- CONTINUEDUnit Size--- S e r i e sIndoor ModelCoolingCapacityARI Standard RatingsCooling HeatingFurnace ModelFactoryEnhanceSta

Page 4 - ACCESSORIES

12COMBINATION RATINGS -- CONTINUEDU n i t S i z e ---SeriesIndoor ModelCoolingCapacityARI Standard RatingsCooling HeatingFurnace ModelFactoryEnhanceSt

Page 5 - ACCESSORY USAGE GUIDELINE

13COMBINATION RATINGS -- CONTINUEDU n i t S i z e ---SeriesIndoor ModelCoolingCapacityARI Standard RatingsCooling HeatingFurnace ModelFactoryEnhanceSt

Page 6

14COMBINATION RATINGS -- CONTINUEDU n i t S i z e ---SeriesIndoor ModelCoolingCapacityARI Standard RatingsCooling HeatingFurnace ModelFactoryEnhanceSt

Page 7 - A--WEIGHTED SOUND POWER (DBA)

15COMBINATION RATINGS -- CONTINUEDU n i t S i z e ---SeriesIndoor ModelCoolingCapacityARI Standard RatingsCooling HeatingFurnace ModelFactoryEnhanceSt

Page 8 - DIMENSIONS

16COMBINATION RATINGS -- CONTINUEDU n i t S i z e ---SeriesIndoor ModelCoolingCapacityARI Standard RatingsCooling HeatingFurnace ModelFactoryEnhanceSt

Page 9 - HEATING CAPACITY, MBTUH

17COMBINATION RATINGS -- CONTINUEDU n i t S i z e ---SeriesIndoor ModelCoolingCapacityARI Standard RatingsCooling HeatingFurnace ModelFactoryEnhanceSt

Page 10 - COMBINATION RATINGS

18DETAILED COOLING CAPACITIESEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES deg F75 85 95 105 115 125CFMEWBCapacityMBtuh†TotalSys-temKW**CapacityMBt

Page 11

19DETAILED COOLING CAPACITIES -- CONTINUEDEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES deg F75 85 95 105 115 125CFM EWBCapacityMBtuh†TotalSystemKW

Page 12

2MODEL NUMBER NOMENCLATURE12345678910111214N N N A A/N N N N N A/N A/N N A21 3 R N A 036 0 0 0 0Prod-uctFamilyTier SEER Major Series Voltage Var iatio

Page 13

20DETAILED COOLING CAPACITIES -- CONTINUEDEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES deg F75 85 95 105 115 125CFM EWBCapacityMBtuh†TotalSys-temK

Page 14

21DETAILED COOLING CAPACITIES -- CONTINUEDEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES deg F75 85 95 105 115 125CFM EWBCapacityMBtuh†TotalSys-temK

Page 15

22DETAILED COOLING CAPACITIES -- CONTINUEDEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES deg F75 85 95 105 115 125CFM EWBCapacityMBtuh†TotalSystemKW

Page 16

23DETAILED COOLING CAPACITIES -- CONTINUEDEVAPORATOR AIRCONDENSER ENTERING AIR TEMPERATURES deg F75 85 95 105 115 125CFM EWBCapacityMBtuh†TotalSystemK

Page 17

24DETAILED COOLING CAPACITIES -- CONTINUEDEVAPORATORAIRCONDENSER ENTERING AIR TEMPERATURES deg F75 85 95 105 115 125CFM EWBCapacityMBtuh†TotalSystemKW

Page 18 - DETAILED COOLING CAPACITIES

25HEAT PUMP HEATING PERFORMANCEINDOOR AIROUTDOOR COIL ENTERING AIR TEMPERATURES deg F--- 3 7 17 27 37 47 57 67EDB CFMCapacityMBtuhTot a lSys-temKW†Cap

Page 19 - See notes on pg. 24

26HEAT PUMP HEATING PERFORMANCE -- CONTINUEDINDOOR AIROUTDOOR COIL ENTERING AIR TEMPERATURES deg F--- 3 7 17 27 37 47 57 67EDB CFMCapacityMBtuhTot a l

Page 20

27HEAT PUMP HEATING PERFORMANCE -- CONTINUEDINDOOR AIROUTDOOR COIL ENTERING AIR TEMPERATURES deg F--- 3 7 17 27 37 47 57 67EDB CFMCapacityMBtuhTot a l

Page 21

28HEAT PUMP HEATING PERFORMANCE -- CONTINUEDINDOOR AIROUTDOOR COIL ENTERING AIR TEMPERATURES deg F--- 3 7 17 27 37 47 57 67EDB CFMCapacityMBtuhTot a l

Page 22

29HEAT PUMP HEATING PERFORMANCE -- CONTINUEDINDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES deg F--- 3 7 17 27 37 47 57 67EDB CFMCapacityMBtuhTot a

Page 23

3PHYSICAL DATAUNIT SIZE --- SERIES 018---A 024---A 030---A 036---A 042---A 048---A 060---AOperating Weight (lb) 159 160 208 211 233 269 295Shipping We

Page 24

30HEAT PUMP HEATING PERFORMANCE -- CONTINUEDINDOOR AIROUTDOOR COIL ENTERING AIR TEMPERATURES deg F--- 3 7 17 27 37 47 57 67EDB CFMCapacityMBtuhTot a l

Page 25 - HEAT PUMP HEATING PERFORMANCE

31HEAT PUMP HEATING PERFORMANCE -- CONTINUEDINDOOR AIROUTDOOR COIL ENTERING AIR TEMPERATURES deg F--- 3 7 17 27 37 47 57 67EDB CFMCapacityMBtuhTot a l

Page 26 - See notes on pg. 31

32GUIDE SPECIFICATIONSGENERALSystem DescriptionOutdoor-- mounted, air --cooled, split -- system heat pump unitsuitable for ground or rooftop installat

Page 27

4ACCESSORY THERMOSTATSTHERMOSTAT / SUBBASE PKG. DESCRIPTIONTSTATBBPRH01---B*Thermidistatt Control — Non---Programmable/Programmable Thermostat withHum

Page 28

5ACCESSORY USAGE GUIDELINEAccessoryREQUIRED FOR LOW ---AMBI-ENT APPLICATIONS(Below 55° F)REQUIRED FOR LONGLINE APPLICATIONS*(Over 80 Ft.)REQUIRED FOR

Page 29

6Accessory Description and Usage (Listed Alphabetically) -- CONTINUED11. Outdoor Air Temperature SensorDesigned for use with Bryant Thermostats listed

Page 30 - Seenoteonpg.31

7ELECTRICAL DATA(VOLTAGE)UNIT SIZE--- S E R I E SV/PHOPER VOLTS* COMPR FANMCAMINWIRESIZE{MINWIRESIZE{MAXLENGTH(FT)}MAXLENGTH(FT)}MAXFUSE**or CKTBRKAMP

Page 31

8DIMENSIONSNOTE: Optional “G” dense coil guard shown.213R

Page 32 - PRODUCTS

9213RN(A,G) BALANCE POINT WORKSHEET0.0010.0020.0030.0040.0050.0060.0070.0080.00--100 1020304050 607080OUTDOOR TEMPERATURE, ºFBUILDING HEAT LOSS, UNIT