Bryant 602A Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes Bryant 602A. Bryant 602A User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
SINGLE-PACKAGED
HEAT PUMP UNITS
Model 602A
Sizes 024-060
2 To 5 Nominal Tons
Form No. PDS 602A.24.4
Single-Packaged Heat Pump for Residential and Light
Commercial Applications
Low Sound Levels
12 SEER
FEATURES/BENEFITS
One-piece heat pump with optional electric heater, low
installation cost, dependable performance and easy
maintenance.
EFFICIENT OPERATION
High-efficiency design with SEERs (Seasonal Energy Efficiency
Ratios) of 12.0 and HSPFs (Heating Seasonal Performance
Factors) of up to 7.2
EASY INSTALLATION
Factory-assembled package is a compact, fully self-contained,
heat pump unit that is pre-wired, pre-piped, and pre-charged for
minimum installation expense. 602A units are available in a
variety of standard capacity ranges with voltage options to meet
residential and light commercial requirements. Units install
easily on a rooftop or at ground-level.
DURABLE, DEPENDABLE COMPONENTS
Scroll Compressors are designed for high efficiency. Each
compressor is hermetically sealed against contamination to help
promote longer life and dependable operation. Vibration isolation
provides quiet operation. Compressors have internal high-
pressure and overcurrent protection.
Direct-drive multi-speed,
PSC (permanent split capacitor)
blower motor is standard on all 602A models.
Direct-drive,
PSC condenser-fan motors are designed to help
reduce energy consumption and provide for cooling operation
down to 40°F outdoor temperature. Motormaster® II low ambient
kit is available as a field-installed accessory and does not require
a special motor.
Corporate thermostats
work with Bryant’s small packaged
products as a system to promote year round comfort.
Refrigerant system
is designed to provide dependability. Liquid
refrigerant strainers are used to promote clean, unrestricted
operation. Each unit leaves the factory with a full refrigerant charge.
Refrigerant service connections make checking operating
pressures easier.
Low Pressure/Loss of Charge Switch
assures added safety and
reliability for the compressor.
Indoor and outdoor coils
are computer-designed for optimum
heat transfer and cooling efficiency. The indoor coil is fabricated
from copper tube and aluminum fins and is located inside the unit
for protection against damage. The outdoor coil is internally
mounted on the top tier of the unit. A FIOP (Factory-Installed
Option) metal louvered grille is available on all models. Copper fin
coils and pre-coated fin coils are available from the factory by
special order. These coils are recommended in applications
where aluminum fins are likely to be damaged due to corrosion.
They are ideal for seacoast applications.
Low sound ratings
ensure a quiet indoor and outdoor
environment with sound ratings as low as 72 dB.
(See page 3.)
Easy to service cabinets
provide easy single-panel accessibility
to serviceable components during maintenance and installation.
The unit base with integrated drain provides easy ground level
installation with or without a mounting pad. Convenient handholds
are provided to manipulate the unit on the jobsite. A nesting
feature ensures a positive unit base to roof curb seal when the unit
is roof mounted. A convenient 3/4-in. wide perimeter flange makes
frame mounting on a rooftop easy.
UNIT 602A
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - Sizes 024-060

SINGLE-PACKAGEDHEAT PUMP UNITS Model 602ASizes 024-060 2 To 5 Nominal TonsForm No. PDS 602A.24.4 Single-Packaged Heat Pump for Residential and Light

Page 2 - TABLE OF CONTENTS

—10— 602A CORNER WEIGHTS (IN POUNDS)SELECTION PROCEDURE (WITH EXAMPLE) I Determine cooling and heating requirements at design conditions: Given:Requ

Page 3 - Model number nomenclature

—11— PERFORMANCE DATA COOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60 *At 75°F

Page 4

—12— PERFORMANCE DATA (cont) COOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60 *A

Page 5

—13— PERFORMANCE DATA (cont) COOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60 *A

Page 6 - MANUAL OUTSIDE AIR DAMPER

—14—PERFORMANCE DATA (cont)COOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60*At 75°F

Page 7

—15—PERFORMANCE DATA (cont)COOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60*At 75°F

Page 8

—16—PERFORMANCE DATACOOLING EXTENDED PERFORMANCE TABLEHEATING EXTENDED PERFORMANCE TABLE -10–20HEATING EXTENDED PERFORMANCE TABLE 30–60*At 75°F enteri

Page 9 - ACCESSORY DIMENSIONS

—17—PERFORMANCE DATA (CONT)ECONOMIZER 1-in. FILTER PRESSURE DROP (in. wg)MULTIPLICATION FACTORSExample: 20 kW (at 240v) heater on 230v= 20.0 (.92 mult

Page 10

—18—WET COIL AIR DELIVERY UNIT602A024-060**Air delivery values are based on operating voltage of 230 v or 460 v, wet coil, without filter or electric

Page 11 - PERFORMANCE DATA

—19—TYPICAL PIPING AND WIRINGINDOORTHERMOSTATDISCONNECTPER NECFROMPOWERSOURCERETURNAIRTOP COVER

Page 12 - PERFORMANCE DATA (cont)

—2— Downflow operation is easily provided in the field to allow vertical ductwork connections. The unit base utilizes knockout style seals on the bott

Page 13

—20—APPLICATION DATACondensate trap — A 2-in. condensate trap must be fieldsupplied.Ductwork — Secure downflow discharge ductwork to roof curb.For hori

Page 14

—21—ELECTRICAL DATA*Heater capacity (KW) based on heater voltage of 208v, 240v, & 480v. If power distribution voltage to unit varies from rated he

Page 15

—22—ELECTRICAL DATA LEGEND452=5v457=7v455=2vLEGENDFLA — Full Load AmpsLRA — Locked Rotor AmpsMCA — Minimum Circuit AmpsMOCP — Maximum Overcurrent Prot

Page 16

—23—208/230-1-60C00133

Page 17 - PERFORMANCE DATA (CONT)

—24—208/230-3-60C00134

Page 19 - TYPICAL PIPING AND WIRING

—26—CONTROLSSEQUENCE OF OPERATIONWhen power is supplied to unit, the transformer (TRAN) isenergized.On units with crankcase heater, heater is also ene

Page 20 - APPLICATION DATA

—27—GUIDE SPECIFICATIONSPackaged Heat PumpsConstant Volume ApplicationHVAC Guide SpecificationsSize Range: 2 to 5 Tons, Nominal CoolingBryant Model Nu

Page 21 - ELECTRICAL DATA

—28—SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICEUNIT MUST BE INSTALLED IN ACCORDANCEWITH INSTALLATION INSTRUCTIONSForm: PDS 602A.24.4Cancels: PDS 6

Page 22 - ELECTRICAL DATA LEGEND

—3— Model number nomenclature 602A 024Model No. 602A – Single Packaged Heat Pump Nominal Cooling Capacity (Tons)024 – 2 030 – 2-1/2 03

Page 23 - 208/230-1-60

—4— OUTDOOR SOUND: OCTAVE BAND DATA - DECIBELS dB — Sound Level (decibels) PHYSICAL DATA * Air filter pressure drop for non-standard filters must not e

Page 24 - 208/230-3-60

—5— Factory-installed optionsLouvered grille provides hail and vandalism protection. A wire grille is standard on all models. See model number nomen

Page 25 - 460-3-60

—6—ECONOMIZERFILTER RACKMANUAL OUTSIDE AIR DAMPER

Page 26 - CONTROLS

—7— BASE UNIT DIMENSIONS — 602A024-036 UNITELECTRICALCHARACTERISTICSUNIT WEIGHTUNIT HEIGHTin. [mm]“A”CENTER OF GRAVITYin. [mm]lb kg X Y Z602A024 208/

Page 27 - GUIDE SPECIFICATIONS

—8— BASE UNIT DIMENSIONS – 602A042-060 UNITELECTRICALCHARACTERISTICSUNIT WEIGHTUNIT HEIGHT mm (in.)“A”CENTER OF GRAVITY mm (in.)lb kg X Y Z602A042 20

Page 28

—9— ACCESSORY DIMENSIONS NOTES:1. Roof curb must be set up for unit being installed.2. Seal strip must be applied as required to unit being installed

Commentaires sur ces manuels

Pas de commentaire