BRYANT
®
Occupancy and Vacancy Sensors
Customer Service: (800) 323-2792 • Technical Support: [email protected] • Design and Support Tools available online at www.bryant-electric.com
Bryant Electric • Hubbell Incorporated (Delaware) • 40 Waterview Drive, Shelton, CT 06484 • Phone (800) 323-2972 • FAX (800) 543-0538 • www.bryant-electric.com • Printed in U.S.A. Specications subject to change without notice. Bryant
®
is a registered trademark of Hubbell Incorporated. BLCMHM001 8/11
Wall Switches (Adaptive Technology) Wall Switches (Passive Infrared) Residential Wall Switches (Passive Infrared)
Control Units and Add-a-Relay
Wall Switch Options Accessories
High Bay Fixture Mount Controls Digital Timer Sensing Technologies
Ceiling Sensors (Adaptive Technology) Ceiling Sensors (Non-Adaptive Technology)Wall Mount Sensors (AD Tech)
Control Units
The MSCU provides a 24V DC power supply
for 1 to 4 sensors or sensor/
Add-A-Relay combinations or 1 to 3 for
CU347A. For use with MSD/MSU/MSP
series ceiling and wall mount sensors.
120/277V AC, 50/60 Hz,
15A (INC) / 20A (FL)
MSCU
Add-A-Relay
Bryant MSAR Add-A-Relay contains
an internal relay for control of an
external lighting load. For use with
MSD/MSU/MSP series ceiling and
wall mount sensors.
120/277V AC, 50/60 Hz,
15A (INC) / 20A (FL)
MSAR
Dual Technology (PIR and US)
Combines both passive infrared and ultrasonic
technologies for maximum reliability.
Minimizes false triggering.
Continued detection by only one technology
then keeps lighting on as necessary.
Offers the best performance for most applications.
Ultrasonic (US)
Senses occupancy by bouncing sound waves off
of objects.
Excellent at detecting even minor motion such as
typing and filing.
Does not require an unobstructed line-of-sight.
Ideal for offices with cubicles or restrooms
with stalls.
Passive Infrared (PIR)
Senses occupancy by detecting the movement
of heat emitted from the human body against the
background space.
Requires an unobstructed line-of-sight for detection.
Ideal for detecting major motion (e.g. walking), and
they work best in small, enclosed spaces with high
levels of occupant movement.
x=color: W (White), I (Ivory), BK (Black), GY (Gray) or LA (Light Almond)
Buttons for MSD/MSU Series
One Button
Two Button
No Button
Colors MSD/MSU Series
White
Ivory Gray
Light
Almond Black
Legend
AT PIR US PC
Adaptive Technology Passive Infrared Ultrasonic Photocell
MSD1000 Series
AT PIR US PC
Manual and Auto-On
120V AC 800W (INC) /1000W (FL)
277V AC 1800W; 1000 Sq. Ft.
1 Button, 1 Circuit
2 Button, 2 Circuit
No Button, 1 Circuit
No Button, 2 Circuit
MSD1000x1
MSD1000x2
MSD1000x1N
MSD1000x2N
Standard Series
1 Relay; 120-347V AC
2 Relays; 120-347V AC
MSHB21U
MSHB22U
Wire Guards
For Wall Switch
For Ceiling Mount
For Wall Mount
MSWGS
MSWGC
MSWGW
Adapters
Ceiling Mount
Raceway
Adapter
MSCRA
Enclosure
Ceiling Sensor
Infrared NEMA
4X Enclosure
MSO4X
MSHB21U
AT PIR US PC
Mounts up to 45 ft. high
Note: Must use a Control Unit with MSD, MSU and MSP ceiling sensors.
MSD2000C
AT PIR US PC
24V DC, 33mA
2000 Sq. Ft.
1000 Sq. Ft.
500 Sq. Ft.
MSD2000C
MSD1000C
MSD500C
MSU2000C
AT PIR US PC
24V DC, 33mA
2000 Sq. Ft.
1000 Sq. Ft.
500 Sq. Ft.
MSU2000C
MSU1000C
MSU500C
MSP1500C
AT PIR US PC
24V DC, 33mA
1500 Sq. Ft.
600 Sq. Ft.
MSP1500C
MSP600C
RMS121/RMS120 Series
AT PIR US PC
with Dimming
120V AC 500W
800 Sq. Ft.
Occupancy Sensor
Manual-on and Auto-On
RMS121x
Vacancy Sensor
Auto-On and Auto-Off
RMS120x
x=color: W (White) or I (Ivory)
RMS101/RMS100 Series
AT PIR US PC
One Button
120V AC 500W
800 Sq. Ft.
Occupancy Sensor
Manual-on and Auto-On
RMS101x
Vacancy Sensor
Auto-On and Auto-Off
RMS100x
x=color: W (White) or I (Ivory)
RMS141/RMS140 Series
AT PIR US PC
Heavy Duty
120V AC 800W (INC) / 1000W (FL)
900 Sq. Ft.
Occupancy Sensor
Manual-on and Auto-On
RMS141x
Vacancy Sensor
Auto-On and Auto-Off
RMS140x
x=color: W (White) or I (Ivory)
DT12H
120V AC 800W; 277V AC 1200W
Digital Timer Switch
Dip switch enabled preset intervals
- 5,15 or 30 minutes
- 1, 3, 6, 9 or 12 hours
MSU400 Series
AT PIR US PC
Manual and Auto-On
120V AC 800W (INC) /1000W (FL)
277V AC 1800W; 400 Sq. Ft.
1 Button, 1 Circuit
2 Button, 2 Circuit
No Button, 1 Circuit
No Button, 2 Circuit
MSU400x1
MSU400x2
MSU400x1N
MSU400x2N
MS1200AT Series
AT PIR US PC
Manual and Auto-On
120V AC 800W (INC) /1000W (FL)
277V AC 1800W (FL); 1200 Sq. Ft.
1 Button, 1 Circuit MS1200ATx
x=color: W (White), I (Ivory) or GY (Gray)
MSP2C
AT PIR US PC
Bi-Level Switching
120V AC 800W, 277V AC 1800W
1000 Sq. Ft.
2 Button, Double Pole MSP2C
MS900 Series
AT PIR US PC
Manual
120V AC 800W (INC) /1000W (FL)
277V AC 1800W (FL); 900 Sq. Ft.
120V AC, 1 Button
277V AC, 1 Button
MS900120x
MS900277x
x=color: W (White) or I (Ivory)
MS1200 Series
AT* PIR US PC
Manual or Auto-On
120V AC 800W (INC/FL); 277V AC 1200W (FL)
1200 Sq. Ft.
Auto-On MS1200x
x=color: W (White), or I (Ivory)
MSD2000L120
AT PIR US PC
Line Voltage
2000 Sq. Ft.
120V AC 2400W
277V AC 5000W
MSD2000L120
MSD2000L277
Note: Must use a Control Unit
with MSD and MSP wall sensors.
MSD1600W
AT PIR US PC
24V 33mA
1600 Sq. Ft. MSD1600W
MSP1600W/MSP120HB
AT PIR US PC
24V 33mA
1600 Sq. Ft. MSP1600W
For High Bay Applications
120 Linear Sq. Ft. MSP120HB
MSP1500CL
AT PIR US PC
Line Voltage
800W (INC); 1000W (FL) @ 120V AC
1800W (FL) @ 277V AC
2200W (FL) @ 347V AC
1500 Sq. Ft MSP1500CL
MSU1500L120
AT PIR US PC
Line Voltage
2000 Sq. Ft.
120V AC 2400W
277V AC 5000W
MSU2000L120*
MSU2000L277*
1500 Sq. Ft.
120V AC 2400W
277V AC 5000W
MSU1500L120
MSU1500L277
*Not Shown
Scan for Available
Rebates By State
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Occupancy and Vacancy Sensors

BRYANT® Occupancy and Vacancy SensorsCustomer Service: (800) 323-2792 • Technical Support: [email protected] • Design and Support Tools availa

Page 2 - Minor Motion:

BRYANT® Occupancy and Vacancy SensorsCustomer Service: (800) 323-2792 • Technical Support: [email protected] • Design and Support Tools availa

Commentaires sur ces manuels

Pas de commentaire