SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and
air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered
equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the
literature and on the tags, stickers, and labels that are attached to the equipment.
January 2014
SSP-SVX15C-EN
Split System Air Conditioners
Odyssey
R-22 Dry Charge
Heat Pump Condenser 7.5, 10, 15 and 20 Tons
((6600 HHzz))
TWA090A***G*
TWA120A***G*
TWA180B***G*
TWA240B***G*
Installation, Operation,
and Maintenance
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - Installation, Operation

SSAAFFEETTYY WWAARRNNIINNGGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating,

Page 2 - Introduction

10SSP-SVX15C-ENDimensional DataFigure 2. Height, width and depth measurementsHWDHWDH - in. (mm) W - in. (mm) D - in. (mm)TWA090A39.125 (993.8) 42.125

Page 3 - Revision History

SSP-SVX15C-EN11Figure 3. 7.5 ton heat pump, single compressorBOTTOMOF UNIT14 3/8"(365.1)26 15/16"(684.2)39 3/16"(995.4)3 1/16" (77

Page 4 - Table of Contents

12SSP-SVX15C-ENFigure 4. 10 ton heat pump, single compressorBOTTOMOF UNIT51 15/16"(1319.2)50 15/16"(1293.8)1/16" (1.6)2 7/8" (73)3

Page 5

SSP-SVX15C-EN13Figure 5. 15, 20 ton heat pump, dual compressorBOTTOM OF UNIT1/16"(1.6)9"(228.6)9"(228.6)25 11/16"(652.5)46"(1

Page 6 - Model Number Description

14SSP-SVX15C-ENWeightsHeat Pump CondenserTable 1. TWA unit and corner weights — lbs (60 Hz)Tons Model No.ShippingMax (lbs)Net Max(lbs)Corner Weights1

Page 7 - General Information

SSP-SVX15C-EN15InstallationRefrigerant Piping GuidelinesFigure 8. Allowable elevation difference: Cooling only TTA above indoor unitContact manufactur

Page 8 - Pre-Installation

16SSP-SVX15C-ENRefrigerant Piping Procedures(Outdoor Units)WWAARRNNIINNGGRR--441100AA RReeffrriiggeerraanntt uunnddeerr HHiigghheerrPPrreessssuurree t

Page 9 - Snow Belt Recommendations

SSP-SVX15C-EN17Refrigerant Piping Procedures(Indoor Unit)Once liquid and suction lines are complete to therefrigerant connections on the indoor unit,

Page 10 - Dimensional Data

18SSP-SVX15C-ENgauge ports.9. Leak test the entire system. Using properprocedures and caution, as described in theprevious section, repair any leaks f

Page 11 - SSP-SVX15C-EN

SSP-SVX15C-EN19Table 3. Estimated charge levels at ARI rated line lengths (25 feet)Matched SetRefrigerant ChargePer CircuitCircuit 1 Circuit 2Liquid L

Page 12

©2014 Trane All rights reservedSSP-SVX15C-ENIntroductionRead this manual thoroughly before operating orservicing this unit.Warnings, Cautions, and Not

Page 13 - FRO NT DETAIL A

20SSP-SVX15C-ENwiring diagrams for accessories are shipped with theaccessory.Unit Power SupplyThe installer must provide line voltage circuit(s) to th

Page 14 - Heat Pump Condenser

SSP-SVX15C-EN21Field WiringFigure 13. Night setback panel field wiringFigure 14. Zone sensor field wiringIInnssttaallllaattiioonn

Page 15 - Installation

22SSP-SVX15C-ENFigure 15. Thermostat field wiringXXRefrigerant CircuitFigure 16. Typical split system heat pump - cooling - refrigerant circuitNote AN

Page 16 - (Outdoor Units)

SSP-SVX15C-EN23Figure 17. Typical split system heat pump - heating - refrigerant circuitNOTE ATXVSDCOMPRESSORNOTE ANOTE AFIELD SUPPLIEDINTER-CONNECTIN

Page 17 - (Indoor Unit)

24SSP-SVX15C-ENElectrical DataTable 4. Electrical characteristics — motors — heat pumps — 60 HzTonsUnit ModelNumberCompressor MotorCondenser Fan Motor

Page 18 - Refrigerant Lines

SSP-SVX15C-EN25Charging Charts and SuperheatFigure 18. TWA090A12515017520022525027530032535037540055 60 65 70 75 80 85 90 95 100 105 110 115 120 125 1

Page 19 - Electrical Wiring

26SSP-SVX15C-ENInstallation ChecklistComplete this checklist once the unit is installed toverify that all recommended procedures have beenaccomplished

Page 20 - NNOOTTIICCEE

SSP-SVX15C-EN27Pre-StartControl Circuit FeaturesNNoottee:: Not all of these features may be required for yourunit, check electrical schematic.Discharg

Page 21 - Field Wiring

28SSP-SVX15C-ENStart-UpReliaTel™™ ControlsThe ReliaTel™ Control is a microelectronic controlfeature, which provides operating functions that aresignif

Page 22 - IInnssttaallllaattiioonn

SSP-SVX15C-EN29ConditionResulting OperationsIf the disconnect switch is in theON position…1. Current is supplied to the compressor crankcase heater(s)

Page 23

SSP-SVX15C-EN3WWAARRNNIINNGGRReeffrriiggeerraanntt uunnddeerr HHiigghh PPrreessssuurree!!FFaaiilluurree ttoo ffoollllooww iinnssttrruuccttiioonnss bbe

Page 24 - Electrical Data

30SSP-SVX15C-ENcooling applications. If the unit is configured with azone sensor, switchover valve 1 (SOV1) and switchovervalve 2 (SOV2) are energized

Page 25 - Charging Charts and Superheat

SSP-SVX15C-EN31Table 7. Heat pump operation with thermostat (continued)Inputs OutputsY1 Y2 G W1 W2 O X2Cool Heat1 Indoor FanDon'tCareDon'tCa

Page 26 - Installation Checklist

32SSP-SVX15C-ENTable 10. Heat pump control (2-step mechanical heating) (continued)Active UnitModeStageIndoor FanCompressorAuxiliaryHeat 1AuxiliaryHeat

Page 27 - Pre-Start

SSP-SVX15C-EN33Service Test Modes for ReliaTel™™ ControlsTest ModesUpon power initialization, the RTRM performs self-diagnostic checks to ensure that

Page 28 - Start-Up

34SSP-SVX15C-ENTroubleshootingTroubleshooting ReliaTel™ControlsWWAARRNNIINNGGLLiivvee EElleeccttrriiccaall CCoommppoonneennttss!!FFaaiilluurree ttoo f

Page 29 - SSttaarrtt--UUpp

SSP-SVX15C-EN35System FailureCheck the voltage between terminals 6 and 9 on J6, itshould read approximately 32 VDC. If no voltage ispresent, a System

Page 30 - Demand Defrost

36SSP-SVX15C-ENThis indicator is usually used to indicate an airside fanfailure.The RTRM will ignore the closing of this NormallyOpen switch for 2 (±1

Page 31

SSP-SVX15C-EN37Test 4 - LED Indicator Test (SYS ON,HEAT, & COOL)WWAARRNNIINNGGLLiivvee EElleeccttrriiccaall CCoommppoonneennttss!!FFaaiilluurree t

Page 32

38SSP-SVX15C-ENMaintenanceWWAARRNNIINNGGHHaazzaarrddoouuss VVoollttaaggee ww//CCaappaacciittoorrss!!FFaaiilluurree ttoo ddiissccoonnnneecctt ppoowweer

Page 33 - Test Modes

SSP-SVX15C-EN39Maintenance LogDateAmbientTemp.(°F)Evaporator Entering Air CompressorSuperheat (°F)(at compressor)Subcooling (°F)(at service valve)DryB

Page 34 - Troubleshooting

4SSP-SVX15C-ENModel Number Description. . . . . . . . . . . . . . . . . 6Heat Pump Condenser . . . . . . . . . . . . . . . . . . . . 6General Informat

Page 35 - Service Indicator

Wiring Diagram MatrixTable 14. Wiring schematics R-22 heat pumpR–22 UnitPower Diagram Connection DiagramTWA090A30RGA 231304570100 231304610100TWA090A4

Page 36 - Temperature Tests

SSP-SVX15C-EN5Maintenance Log . . . . . . . . . . . . . . . . . . . . . . . . 39Wiring Diagram Matrix . . . . . . . . . . . . . . . . . . . . 40Chargi

Page 37 - Sensor Test

6SSP-SVX15C-ENModel Number DescriptionHeat Pump CondenserT W A 120 A 3 0 0* *1 2 3 4 5 6 7 8 9 10 11 12All products are identified by a multiple-chara

Page 38 - Maintenance

SSP-SVX15C-EN7General InformationThis manual describes proper installation, operation,and maintenance procedures for air-cooled systems. Bycarefully r

Page 39 - Maintenance Log

8SSP-SVX15C-ENPre-InstallationUnit InspectionInspect material carefully for any shipping damage. Ifdamaged, it must be reported to, and claims madeaga

Page 40 - Wiring Diagram Matrix

SSP-SVX15C-EN9Unit MountingWWAARRNNIINNGGMMoouunnttiinngg IInntteeggrriittyy!!FFaaiilluurree ttoo ffoollllooww iinnssttrruuccttiioonn bbeellooww ccoou

Commentaires sur ces manuels

Pas de commentaire