Form No. PDS 550A.24.10
DELUXE 13 SEER
AIR CONDITIONER
WITH PURON
®
REFRIGERANT
550A
Sizes 024 thru 060
Bryant’s Air Conditioners with Puron® refrigerant provide a col-
lection of features unmatched by any other family of equipment.
The 550A family has been designed utilizing Bryant’s Puron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth’s
ozone layer. Bryant’s 550A system meets the Energy Star®
guidelines for energy efficiency.
FEATURES
Puron Environmentally Sound Refrigerant
—Is Bryant’s
refrigerant designed to help protect the environment. Puron is
an HFC refrigerant which does not contain chlorine that can
harm the ozone layer. The most important advantage of Puron
refrigerant is that it has not been banned in future air condition-
ing systems as the traditional refrigerant R-22 has been. Puron
refrigerant is in service in thousands of systems proving highly
reliable, environmentally sound performance.
Bryant’s Evolution™ Controls
—These industry-leading con-
trols, when installed with Bryant’s Perfect Humidity™ variable-
speed furnaces or fan coils, provide the homeowner with:
–unparalleled control of temperature, humidity, indoor air quality,
and zoning
–unprecedented ease of use
–simple operation through on-screen, text-based service
reminders
Optional remote access through telephone or Internet is also
available when combined with a remote connectivity kit.
Heavy Duty Inlet Grille
—The DuraGuard™ coil protector,
made of a coated steel wire grid with vertical 3/8 in. spacing, is
designed to help protect the coil from inclement weather, van-
dalism, and incidental damage. It provides protection while not
restricting airflow and maintaining ease of coil inspection and
cleaning.
High Efficiency Performance
—Is delivered through a combi-
nation of features including Bryant’s Puron refrigerant, unique
scroll compressor, and advanced heat transfer surfaces. Effi-
ciency ratings are 13 SEER (Seasonal Energy Efficiency
Ratio) with enhanced ratings of up to 14.5 SEER. Sophisti-
cated heat transfer surfaces utilized in Bryant’s 550A design
allow heat to easily be transferred to the outdoor air and
require less energy. The unique scroll compressor found in the
550A design performs quietly and adds to the overall efficiency
of the system. For improved serviceability, all models are
equipped with a compressor terminal plug. Finally, Bryant’s
Puron refrigerant operates more efficiently than ordinary R-22
refrigerant found in other systems. The efficiency levels pro-
vided by the 550A provide end users with lower costs of opera-
tion than traditional air conditioning systems.
Assured Future Service
—By utilizing the environmentally
sound refrigerant, Puron, 550A models will remain serviceable
well into the future. The Clean Air Act of 1990 has placed a cap
on production of most other refrigerants which has scheduled
reductions beginning in 2004. The resulting cap in production
ultimately results in a complete ban on many other refrigerants
in new equipment by the year 2010. These changes required by
federal law, mean the supply of other refrigerants may be limited
in the near future making Puron refrigerant the correct choice
when considering long term serviceability.
Highly Reliable Performance
—Is delivered through the supe-
rior design of the system and componentry. The reliability of
the 550A models has been proven to provide the lowest inci-
dence of warranty service of any product in the Bryant family
in the past three years of service. Long term reliability is
assured through the use of both high and low pressure
switches which will not allow the system to operate in the
event of a significant change in operating pressure. In doing
this, the system is protected from damage if an unusual condi-
tion arises. Finally, Bryant includes a special liquid line filter
drier designed to trap moisture and contaminants which could
otherwise shorten the life of the system.
Bryant’s AeroQuiet System
Is one of the most sought after
features of the 550A family. Extremely low operating sound is the
result of special attention to the air moving through the outdoor
unit, a specially designed sound enclosure surrounding the com-
pressor, and an exclusive laminated plate beneath the compres-
sor to eliminate sound transmission to the rest of the system.
Application Versatility
—Bryant’s systems utilizing Puron
refrigerant have the same application guidelines as other sys-
tems. Applications which include long line sets (50 to 175 ft) or
applications which require the system to operate at low outdoor
temperatures (below 55°F) are approved under Bryant’s stan-
dard guidelines.
Bryant Coils and Fan Coils to Complete the System
—Bryant
specially designs both the outdoor product and indoor coil prod-
ucts to operate with assured reliability and performance. A wide
range of indoor coil options are listed in the ratings sections of
this publication.
Special Protective Devices
—High and low pressure switches
and internal protection in the compressor including temperature
and current sensing overloads prevent operation under poten-
tially damaging circumstances. A special liquid line filter drier
designed to trap nearly 4 times the volume of contaminants of
standard driers provides superior protection from moisture
trapped in the system.
Electrical Range
—208/230v, single phase.
Wide Range of Sizes
—Available in six sizes; 2, 2-1/2, 3, 3-1/2,
4, and 5 ton.
Cabinet
—Galvanized steel is coated with powder paint to pro-
vide superior long-lasting protection and appearance.
Totally Enclosed Fan Motor
—Protected from adverse weather
conditions.
Unit Design
—Enhanced copper and aluminum heat transfer
surfaces with vertical air discharge to direct air up and away
from the area.
External Service Valves
—Both service valves are back seating
type valves which are externally located. These unique valves
allow service technicians to evacuate or charge the system in
less time than standard service valves.
Easy Serviceability
—Removal of one panel provides access to
both electrical and refrigerant carrying components simplifying
installation and service.
Agency Approvals
—550A models are listed with UL (U.S. and
Canada), ARI, and CEC. Special endorsements have also been
awarded these products by Energy Star® which recognizes
energy efficient products.
Limited Warranty
—A standard five year warranty on parts
with extended warranty coverage on the compressor for a
total of 10 years. A five year warranty is offered on the out-
door coil. Optional warranties are available through your
Bryant distributor.
TM
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1 - Sizes 024 thru 060

Form No. PDS 550A.24.10 DELUXE 13 SEERAIR CONDITIONERWITH PURON ® REFRIGERANT 550A Sizes 024 thru 060 Bryant’s Air Conditioners with Puron® refriger

Page 2 - DIMENSIONS

—10— 030-FFF1DNA030 28,600 TDR 12.50 — 12.50 11.05FG3AAA036 28,400 NONE — 12.50 12.50 11.00FK4(C,D)NF001 29,000 TDR&TXV 13.00 — — 11.95FK4(C,D)NF

Page 3 - ISO 9001:2000

—11— 030-F COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,600 TDR 13.50 — 13.50 11.90CC5A/CD5AW030 28,400 TDR 13.20 — 13.20 11.50CE3AA0

Page 4 - SPECIFICATIONS

—12—036-FCK5PE042 35,000 TDR&TXV 14.00 — — 12.20CK5PT036 35,000 TDR&TXV 13.50 — — 12.05CK5PT042 35,000 TDR&TXV 14.00 — — 12.15CK5PW036 35,

Page 5 - SPECIFICATIONS Continued

—13—036-FCK3BA042 35,000 TDR 13.50 — 13.50 11.75CK5A/CK5BA042 35,000 TDR 13.50 — 13.50 11.75CK5A/CK5BT042 35,000 TDR 13.50 — 13.50 11.75CK5A/CK5BW036

Page 6

—14—036-GFV4BNF003 35,000 TDR&TXV 14.00 — — 12.40FV4BNF005 36,000 TDR&TXV 14.50 — — 12.85FX4BNF036 35,000 TDR&TXV 12.50 — — 11.20FX4BNF042

Page 7

—15—036-GCOILS + 355MAV042040 VARIABLE-SPEED FURNACECC5A/CD5AA042 34,400 TDR 13.50 — 13.50 11.85CC5A/CD5AW036 34,400 TDR 13.50 — 13.50 11.85CC5A/CD5AW

Page 8 - COMBINATION RATINGS

—16—036-GCK3BA036 34,600 TDR 13.50 — 13.50 12.00CK3BA042 34,600 TDR 13.50 — 13.50 12.05CK5A/CK5BA036 34,600 TDR 13.50 — 13.50 12.00CK5A/CK5BA042 34,60

Page 9

—17—042-FCC5A/CD5AW048 40,500 TDR 14.00 — 14.00 11.95CD5AA048 40,500 TDR 14.00 — 14.00 11.90CE3AA042 40,500 TDR 13.50 — 13.50 11.85CE3AA048 41,000 TDR

Page 10 - COMBINATION RATINGS Continued

—18—042-FCK5PT042 40,500 TDR&TXV 13.00 — — 11.30CK5PT048 40,500 TDR&TXV 13.20 — — 11.55COILS + 355MAV060080 VARIABLE-SPEED FURNACECC5A/CD5AA04

Page 11

—19—048-FCOILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACECC5A/CD5AA060 46,000 TDR 13.00 — 13.00 12.00CC5A/CD5AC048 45,000 TDR 13.00 — 13.00 11.70CC5A/C

Page 12

—2— DIMENSIONS A99067 AIR DISCHARGEAIR DISCHARGEAIR INAIR INAIR IN3/8" DIA. TIEDOWN KNOCKOUTS(2) PLACESLKJEDCLNOTES:1. ALLOW 30" CLEAR

Page 13

—20—048-FCK5PA060 46,500 TDR&TXV 13.00 — — 11.70CK5PT060 46,500 TDR&TXV 13.00 — — 11.70CK5PX060 47,500 TDR&TXV 13.50 — — 12.05COILS + 355M

Page 14

—21—COMBINATION RATINGS ContinuedUNITSIZE-SERIESINDOORMODELTOT. CAP.BTUHFACTORY-SUPPLIEDENHANCE-MENTSEEREERStandardRatingBryant Gas Furnace or Accesso

Page 15

—22—*Tested combination.† In most cases, only one method should be used to achieve TDR function. Using more than one method in a system may cause degr

Page 16

—23—DETAILED COOLING CAPACITIES*See notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†TotalSyskW*

Page 17

—24—DETAILED COOLING CAPACITIES* continuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 18

—25—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 19

—26—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 20

—27—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 21

—28—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 22

—29—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 23 - DETAILED COOLING CAPACITIES*

—3— RECOMMENDED TUBE DIAMETERS *For tube sets greater than 50 ft horizontal and/or 20 ft vertical differential, consult Residential Split System Appl

Page 24

—30—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 25

—31—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 26

—32—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 27

—33—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 28

—34—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 29

—35—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 30

—36—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 31

—37—DETAILED COOLING CAPACITIES* ContinuedSee notes on page 38.EVAPAIRCONDENSER ENTERING AIR TEMPERATURES °F75 85 95 105 115 125CFM EWBCapacityMBtuh†T

Page 32

—38—DETAILED COOLING CAPACITIES* ContinuedNOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation

Page 33

—39—CONDENSER ONLY RATINGS*See notes on page 40.SST°FCONDENSER ENTERING AIR TEMPERATURES °F55 65 75 85 95 105 115 125550A024-G30TCG 20.9 19.4 17.9 16.

Page 34

—4— SPECIFICATIONS See notes on page 5.. UNIT SIZE-SERIES 024-G 030-F 036-F/G Operating Weight (Lb) 214 202 237 ELECTRICAL Unit Volts—Hertz—Phase 208

Page 35

—40—CONDENSER ONLY RATINGS* Continued* ARI listing applies only to systems shown in Combination Ratings table.KW — Outdoor Unit Kilowatts OnlySDT — Sa

Page 36

—41—SYSTEM DESIGN SUMMARY1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less t

Page 37

—42—

Page 38

—43—

Page 39 - CONDENSER ONLY RATINGS*

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICEUNIT MUST BE INSTALLED IN ACCORDANCEWITH INSTALLATION INSTRUCTIONSCancels: PDS 550A.24.9© 2004 Bryant

Page 40 - 550A042-F

—5— SPECIFICATIONS Continued *Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits m

Page 41 - SYSTEM DESIGN SUMMARY

—6— EVOLUTION™* CONTROLS * When applied with Bryant’s Perfect Humidity™ series 355, 315 and FE Indoor Models.† Must be installed in Dual-Fuel Evoluti

Page 42

—7— ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 5. Crankcase Heater An electric resistance heater which mounts to the base of the compres

Page 43

—8— COMBINATION RATINGS UNITSIZE-SERIESINDOORMODELTOT. CAP.BTUHFACTORY-SUPPLIEDENHANCE-MENTSEEREERStandardRatingBryant Gas Furnace or Accessory TDR†A

Page 44 - GUIDE SPECIFICATIONS

—9— 024-G COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CE3AA024 22,400 TDR 14.00 — 14.00 12.30CE3AA030 22,800 TDR 14.00 — 14.00 12.55 COILS + 355M