Bryant EVOLUTION 577D----A Manuel d'installation Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
4
4. Remove the front access panel.
5. Move the selector switch on the internalgas valveto theOFF
position.
6. Replace the front access panel
7. Restore electrical power to the unit and set system switch to
COOL.
8. Set the temperature selector on UI slightly below the room
temperature to start unit.
To shut off unit electric cooling:
Refer to Fig. 6 while proceeding with the following steps.
1. Setthetemperature selectoron UI to highest temperature set-
ting and set system SWITCH to OFF.
2. Close the external manual shutoff valve.
3. Turn off the electrical power supply to the unit.
55
STEP 1 STEP 2
C
L
O
S
E
STEP 3
OFF
ON
MAIN
STEP 4
STEP 7
OFF
ON
MAIN
STEP 8
STEP 5
72
STEP 10
STEP 6
STEP 9
O
P
E
N
A09133
Fig. 4 -- To Start Unit Gas Heat
Vue de la page 3
1 2 3 4 5 6 7 8

Commentaires sur ces manuels

Pas de commentaire