Advanced Setup
Page 15
Step # Description Range Factory Default
1 Time of day clock set 24 hour 12:00 Am
2 Day of the week Sun - Sat Monday
3 Operating Mode - Heat or Cool Heat / Cool Heat
4 Programmability flag On / Off On
5 Configurable Display 1 / 2 2
6 Deadband or Temperature swing 1 - 6 2
7
8
9
Cycles per hour d, d1, 2 - 6 6
Fahrenheit or Centigrade F / C F
Thermoglow backlight Off / On On
Advanced Setup Table
SINGLE SETPOINT OPERATION
OUTDOOR SENSOR
The thermostat display may be configured such that only the setpoint is
visible.
This is done in Advance Setup Step #5, by selecting 1.
The room temperature may be viewed by holding in the On/Off button for
2 seconds. Releasing the On/Off button will return the display to the previous
screen.
An outdoor temperature sensor may be connected to this thermostat. Totaline
offers wired or wireless models. Compatible models include: P474-0401RF/REC
& P474-0400.
Consult the remote sensor instruction sheet for wiring connections.