Form No. PDS CK5A.18.1
FURNACE N-COILS
CK5A, CK5B
Sizes A018 thru A060
This vertical design N-coil is a furnace coil designed to provide
the highest standards of reliability and durability. The product is
offered in a painted cased (CK5A) or an embossed cased
(CK5B) version. The cased coils are offered in standard, over-
hang, and wide configurations for use in multiple installation ap-
plications. Additionally, the cased coils are offered in a Transition
configuration, which is designed to fit two furnace widths without
field modification.
Easy maintenance is provided as the coil slides out of the cabi-
net after removing the access door and service panel.
The coils are available in sizes 018 through 060 (1-1/2-5 tons).
COMMON FEATURES
Water Management
—The CK coil design does an excellent job
of water management. The coils are designed to avoid water
blow-off into the ducts by directing condensate away from the
fins and into the drain pan. The coils drain pan design provides
improved condensate removal into the drain. This improves in-
door air quality.
Durable Condensate Pan
—Each coil is equipped with a corro-
sion resistant condensate drain pan. The condensate drain pan
is designed with a slope to help ensure proper drainage, im-
proved moisture removal, and home comfort.
Compact Design
—Unique design offers as much as 2 in. less
in height to aid in tight installations.
Brass Inserts
— Every condensate pan features two 3/4 in. fe-
male threaded brass insert connections. The Bryant unique
brass inserts provide for a leak-free condensate line connection
to prevent water damage.
Refrigerant Connections
—The coils are provided with proven
sweat-connections for leak-free operation maintaining system
reliability.
Burst Pressures
—These coils meet or exceed burst pressure
of 2100 psi which is at least three to five times the pressure they
will see in actual application.
External Piston Location
—Provides easy access to the piston
metering device, for quick installations and standard service pro-
cedures.
Liquid Line Bracket
—Holds the piston body in place for quick,
safe piston access without needing a back-up wrench.
Neoprene Ring
—The ring, installed inside the liquid line con-
nection, is the best option for preventing refrigerant leaks and fu-
ture service calls. Neoprene works with both Puron® and R-22
Refrigerant.
Protective Tube Sheets
—Protect the durable copper tubing
from being damaged during the manufacturing and installation
process.
Warranty
—All Bryant coils feature a 1-year limited warranty on
parts, with additional extended warranties available for the
system.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - CK5A, CK5B

Form No. PDS CK5A.18.1 FURNACE N-COILS CK5A, CK5B Sizes A018 thru A060 This vertical design N-coil is a furnace coil designed to providethe highest s

Page 2 - MODEL NUMBER NOMENCLATURE

—2— MODEL NUMBER NOMENCLATURE CK5 C—CoilK—Cased, N-Coil5—Upflow/DownflowCERTIFICATION APPLIES ONLY WHENUSED WITH PROPER COMPONENTSAS LISTED WITH ARI

Page 3

—3— A97606 DIMENSIONS (In.) * In these models the coil can be removed from the casing and installed as an uncased coil without needing to field fabri

Page 4

—4— GROSS COOLING CAPACITIES (MBH) CFM — Cubic Ft per Minute EWB — Entering Wet Bulb (°F) TC — Gross Cooling Capacity 1000 Btuh SHC — Gross Sensible

Page 5 - 81 82 83 84 84 Over 85

—5— GROSS COOLING CAPACITIES (MBH) Continued CFM — Cubic Ft per Minute EWB — Entering Wet Bulb (°F) LWB — Leaving Wet Bulb (°F) TC — Total Cooling Ca

Page 6 - INDOOR COIL PISTONS

—6— COIL STATIC PRESSURE DROP (In. WC)INDOOR COIL PISTONS UNIT SIZE BULB AIR QUANTITY (CFM) A018 400 500 600 700 800 — WET 0.08 0.12 0.16 0.22 0.29 —

Page 7

—7—

Page 8 - SERVICE TRAINING

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICEUNIT MUST BE INSTALLED IN ACCORDANCEWITH INSTALLATION INSTRUCTIONSCancels: PDS CJ5A.18.3© 1999 Bryant