Owner’s Manual
ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT
INSTALLATION!!
DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY!
This manual should remain with the unit.
Not intended for use in critical life support applications.
!
!
Liquid-cooled, Prepackaged
Standby Generators
Model Number:
ASPAS1BBL015
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - Owner’s Manual

Owner’s ManualONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPTINSTALLATION!!DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY!This manual shoul

Page 2 - INTRODUCTION

8 Bryant1.14 ENGINE OIL RECOMMENDATIONSThe unit has been filled with 15W-40 engine oil at thefactory. Use a high-quality detergent oil classified “For

Page 3 - Bryant 1

Bryant 9NOTE:It is essential to use the latest version of any stan-dard to ensure correct and current information.• NFPA No. 37, STATIONARY COMBUSTION

Page 4 - WARNING:

10 Bryant2.5 EMERGENCY CIRCUIT ISOLATIONMETHODThis prevents overloading the generator by keepingelectrical loads below the wattage/amperage capacityof

Page 5 - EXPLOSION HAZARDS

Bryant 112.10 BATTERY INSTALLATIONStandby generators installed with automatictransfer switches will crank and start automati-cally when NORMAL (UTILIT

Page 6 - 4 Bryant

12 BryantBefore starting the generator for the first time, theinstaller must complete the following procedures. Forfollow-up maintenance information a

Page 7 - 1.7 ENGINE PROTECTIVE DEVICES

Bryant 133.1.2 FAULT INDICATOR LAMPThe lamp goes ON when one or more of the followingengine faults occurs and when engine shuts down.• Low oil pressur

Page 8 - 1.10 SPECIFICATIONS

14 Bryant4.1 MAINTENANCE PERFORMED BY AUTHORIZED SERVICE FACILITIES A. EVERY THREE MONTHS1.Check battery state of charge and condition.2.Inspect and t

Page 9 - 1.13 TORQUE SPECIFICATIONS

Bryant 154.4.2 BATTERY FLUIDCheck battery electrolyte fluid at least once a month.Fluid should cover separators in all battery cells. Iffluid level is

Page 10 - INSTALLATION

16 BryantFigure 4.2 - Oil FilterAfter refilling the crankcase with oil, alwayscheck oil level on dipstick. NEVER OPERATEENGINE WITH OIL BELOW THE DIPS

Page 11 - 2.4 BASIC STANDBY ELECTRIC

Bryant 17Finally, have the insulation resistance of stator androtor windings checked. If insulation resistances areexcessively low, the generator may

Page 12 - 10 Bryant

BryantINTRODUCTIONThank you for purchasing a Bryant home standbygenerator system.Every effort was expended to make sure that theinformation and instru

Page 13 - Section 2 — Installation

18 BryantSection 4 — MaintenanceBryant Liquid-cooled 15 kW Generators4.7 SCHEDULED MAINTENANCEThe following is a recommended maintenance schedule for

Page 14 - COMPONENTS

Bryant 19Section 4 — MaintenanceBryant Liquid-cooled 15 kW GeneratorsMaintenance Level 1 Level 2 Level 3 Level 4TasksRecom- Task Required Task Require

Page 15 - 3.4 WEEKLY EXERCISE CYCLE

20 BryantSection 4 — MaintenanceBryant Liquid-cooled 15 kW GeneratorsMaintenance Level 1 Level 2 Level 3 Level 4TasksRecom- Task Required Task Require

Page 16 - OIL DIPSTIC

Bryant 21Section 5 — TroubleshootingBryant Liquid-cooled 15 kW Generators5.1 TROUBLESHOOTING POINTSPROBLEM CAUSE CORRECTIONEngine won’t crank. 1. 15 a

Page 17 - OPERATOR CAN PERFORM

Section 6 — NotesBryant Liquid-cooled 15 kW Generators22 Bryant

Page 18 - OIL FILTER

Bryant 23Section 7 - Installation DiagramBryant Liquid-cooled 15 kW GeneratorsDrawing No. 0E1533-B

Page 19 - 4.6.4 BATTERY REPLACEMENT

2641144 RED11XX3333222211264411332225576TRANSFER SWITCHCONNECTION5464236713111214151618176352FOR PRE-PACK TRANSFER194SWITCH CONNECTIONS(BLACK)(BLACK)N

Page 20 - 4.7 SCHEDULED MAINTENANCE

Bryant 25Section 8 - Electrical DataBryant Liquid-cooled 15 kW GeneratorsElectrical Schematic — Control Panel —Drawing No. 0F5244FL15GCU56117AB141643E

Page 21 - Bryant 19

26 BryantSection 8 - Electrical DataBryant Liquid-cooled 15 kW GeneratorsWiring Diagram — 1.5L Engine — Drawing No. 0E0343-B0ELECTRONICCONTROLLERGOVER

Page 22 - 20 Bryant

Bryant 27Section 8 - Electrical DataBryant Liquid-cooled 15 kW GeneratorsElectrical Schematic — 1.5L Engine — Drawing No. 0A7182-CBWTS - WATER TEMPERA

Page 23 - 5.1 TROUBLESHOOTING POINTS

Table of ContentsBryant Liquid-cooled 15 kW GeneratorsBryant 1INTRODUCTION ...IFCSAFETY RULES ...

Page 24 - Section 6 — Notes

ITEM PART NO. QTY. DESCRIPTION1098290 1 ASM MOTOR STEPPER2098941A 1 HOUSING GOVERNOR CONNECTOR3098958A REF CONNECTOR INTERFACE ASSEMBLY4098942A 1 COVE

Page 25 - Drawing No. 0E1533-B

ITEM PART NO. QTY. DESCRIPTION1 0D8656 1 BASE MOUNTING 1.5L STNRD & ACSTC2 027482 2 WASHER SHAKEPROOF EXT 5/16 STL3 070936 2 DAMPENER VIBRATION4 0

Page 26 - Section 8 - Electrical Data

30 BryantNUTS ITEM #26.USE LOCTITE ONPANEL FOR ACCESSER CABLEWELD STUD UNDER ROOF17GROUND WIRE.FASTENER TO SECUREUSE DOOR LATCHNOTE:112471049242625198

Page 27

ITEM PART NO. QTY. DESCRIPTION1 0D8666 1 ROOF ACSTC&STND CMPRTMNT 1.5L2 0D8664C 1 DUCT CENTER 1.5L3 0D8657 1 SUPPORT RADIATOR 1.5L MITSU4 0D8660 2

Page 28

32 BryantSection 9 - Exploded Views and PartsBryant Liquid-cooled 15 kW GeneratorsControl Panel — Drawing No. 0F52402229265128262510273395867315034491

Page 29

Bryant 33ITEM PART NO. QTY. DESCRIPTION10D9322 1 PANEL BACK & BOTTOM 20D9332 1 PANEL LH SIDE 3 0F5246A 1 PANEL FRONT W/SILKSCREEN40D9330 1 PANEL R

Page 30 - 28 Bryant

61WATERPUMPHARDWARE13910112871224101415166325412439413042424171110141119171820262120252224573311149247210111014124353436444514711246111049477011106692

Page 31 - Bryant 29

ITEM PART NO. QTY. DESCRIPTION1 0A4531 1 ENGINE-1.5L2 022473 2 WASHER FLAT 1/4 ZINC3 057822 1 CLAMP HOSE #8 .53-1.004 0A45310258 1 GASKET-EXHAUST MANI

Page 32 - 30 Bryant

172128(BOTTOM ONLY)28"A"221511162"A"101911512143187641714TUBE (ON BLOCK)271310232619WATER INLET888208ADAPTER1224TO THERMOSTAT67Sec

Page 33 - Bryant 31

ITEM PART NO. QTY. DESCRIPTION1 0D8657 1 SUPPORT RADIATOR 1.5L MITSU2 0A5734 1 RADIATOR 1.5L3 0A6237 1 VENTURI 1.5L MODINE4 * 0A6238 1 GUARD FAN 1.5L

Page 34 - 32 Bryant

Study these SAFETY RULES carefully before installing, operat-ing or servicing this equipment. Become familiar with thisOwner’s Manual and with the uni

Page 35 - Bryant 33

38 Bryant43L.P. VAPORPORT"OUT 2"91340411110"D"1545212425302833201914"C"121716313266392638141403734363522"C"138

Page 36 - Engine — Drawing No. 0F5273

Bryant 39ITEM PART NO. QTY. DESCRIPTION1 * --------- 1 WELDMENT MOUNTING BASE2 075580 1 FLANGE FUEL INLET3 0E1006 1 ASSY REGULATOR 1.5L N.G.OR LPV4039

Page 37 - Bryant 35

40 Bryant8361331259151417To BlowerHousing322324351212872233102916301826192031214To EngineCrankshaft26Section 9 - Exploded Views and PartsBryant Liquid

Page 38 - Radiator — Drawing No. 0F5274

Bryant 41ITEM PART NO. QTY. DESCRIPTION1098671 1 ASSY ROTOR 10KW098681 1 ASSY ROTOR 15KW098675 1 ASSY ROTOR 20KW098936 1 ASSY ROTOR 25KW2 0A5336A 1 HO

Page 39 - Bryant 37

ITEM PART NO. QTY. DESCRIPTION1 077483 REF BATT 12VDC 75-AH 26 (NOT INCLUDED)2 038804D 1 CABLE BATT RED #4 X 20.003 038805B 1 CABLE BATT BLK #4 X 23.0

Page 40 - L.P. VAP

Bryant 43ITEM PART NO. QTY. DESCRIPTION1 0A4355 1 MANIFOLD EXHAUST 1.5L2 0E2844 1 NIPPLE TOE 1.5NPTX5.5 BLK IRON3 036434 3 BOLT U 5/16-18 X 2.09036449

Page 41 - Bryant 39

44 BryantSection 10 – WarrantyBryant Liquid-cooled 15 kW GeneratorsCALIFORNIA EMISSION CONTROL WARRANTY STATEMENTYOUR WARRANTY RIGHTS AND OBLIGATIONST

Page 42

Bryant 45EMISSION CONTROL SYSTEM WARRANTYEmission Control System Warranty (ECS Warranty) for 1995 and later model year engines:(a) Applicability: This

Page 43 - Bryant 41

Section 10 – WarrantyBryant Liquid-cooled 15 kW GeneratorsBRYANT "TWO YEAR" LIMITED WARRANTY FOR "PREPACKAGED EMERGENCY AUTOMATIC STAND

Page 44 - 42 Bryant

place before operating the generator. If work must be donearound an operating unit, stand on an insulated, dry surfaceto reduce shock hazard.• Do not

Page 45

4 Bryant1.1 GENERATORThis equipment is a liquid-cooled, engine-driven gen-erator set. The generator is designed to supply elec-trical power that opera

Page 46 - 44 Bryant

Bryant 51.6 GENERATOR FUEL SYSTEMThe generator has been factory tested and adjustedusing a natural gas fuel system. If propane (LPrequirements) gas is

Page 47 - Section 10 – Warranty

6 BryantFigure 1.6 - Low Coolant Level Sensor1.7.4 OVERSPEED SHUTDOWNThe Pre-pack circuit board on liquid cooled unitsreceives AC frequency (rpm) sign

Page 48

1.10.2 ENGINE SPECIFICATIONSMake....................MitsubishiDisplacement .....