Vue de la page 0
Installation Instructions
GAPAB
PERFECT AIRt AIR PURIFIER FOR FAN COILS
SIZES 1620, 2020, AND 2420
NOTE: Read the entire instruction manual before starting the
install.
TABLE OF CONTENTS
PAGE
INTRODUCTION 1....................................
HOW IT WORKS 1....................................
SAFETY CONSIDERATIONS 1..........................
APPLICATION CONSIDERATIONS 2....................
INSTALLATION 3--6...................................
START--UP AND OPERATION 7.........................
MAINTENANCE 7 -- 8.................................
TROUBLESHOOTING 9................................
SPECIFICATIONS AND DIMENSIONS 10.................
WARRANTY 11.......................................
INTRODUCTION
Congratulations for selecting the Perfect Airt Air Purifier for
your home comfort system! The Perfect Airt Air Purifier is
proven to remove and kill airborne germs and allergens, including
viruses, bacteria, and mold spores. The Perfect Airt Air Purifier
is a cornerstone of Bryant’s Healthy Home Solutions for
providing healthier, cleaner air in your home.
HOW IT WORKS
The Perfect Airt Air Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Perfect Airt Air Purifier
treats the entire air--stream through a state of the art, three--stage
process, exclusive to Bryant.
In stage one, the particles are electrically charged by a
precision--point ionization array as they enter the Perfect Airt
Air Purifier.
In stage two, the charged particles are electrically attracted to the
air purification cartridge, which is located within an electric field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
The Perfect Airt Air Purifier is CSA certified for shock and
electrical fire hazard only.
La Perfect Airt Air Purifier certification CSA vise uniquement
les risques de choc electrique et.
A06367
Fig. 1 --- GAPAB Unit
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock or
other conditions which may cause personal injury or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory authorized kits or accessories
when modifying this product. Refer to t he individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses and work gloves.
Have a fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions attached to the
unit. Consult local building codes and National Electrical Code
(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol
. When you see this symbol on the unit
and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words DANGER,
WARNING, and CAUTION. These words are used with the
safety--alert symbol. DANGER identifies the most serious
hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal
injury or death. CAUTION is used to identify unsafe practices
which may result in personal i njury or product and property
damage. NOTE is used to highlight suggestions which will result
in enhanced installation, reliability, or operation.
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Installation Instructions

Installation InstructionsGAPABPERFECT AIRt AIR PURIFIER FOR FAN COILSSIZES 1620, 2020, AND 2420NOTE: Read the entire instruction manual before startin

Page 2 - APPLICATION CONSIDERATIONS

10SPECIFICATIONS AND DIMENSIONSTable 1—Specifications and DimensionsSpecifications GAPABXBB1620 GAPABXBB2020 GAPABXBB2420Color Taupe Metallic Taupe Me

Page 3 - INSTALLATION

11WARRANTYFOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER:FIRST: Contact the installer. You may find their name on the product or in your Homeowner

Page 4 - Adapters (x4)

12Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.EB

Page 5

2PERSONAL INJURY HAZARDFailure to follow this caution may result in personal injury.Ozone in concentrations above 0.05 PPM may behazardous to health.D

Page 6

3INSTALLATIONStep 1 —Check Perfect Airt Air Purifier ComponentsCUT HAZARDFailure to follow this caution may result in personal injury.Sheet metal part

Page 7 - Power Indicator

4Step 3 —Mount Cabineta. Turn off power to the heating and cooling system.b. Remove the existing fan coil filter and discard. Excessivesystem static p

Page 8 - Tip of point after cleaning

5Step 4 —Wiringa. Ensure power has been removed from the heating andcooling system.b. Turn the Perfect Airt Air Purifier power switch off.c. Connect t

Page 9 - TROUBLESHOOTING

6TO FAN COIL FIELD POWER CONNECTIONFUSED POWER CONNECTOR LEADSFROM INSTALLATION COMPONENTS(IN BAG ATTACHED TO POWER CORD)AIR PURIFIERPOWER CORDTO FAN

Page 10 - SPECIFICATIONS AND DIMENSIONS

7START--UP AND OPERATIONStep 1 —Checking Air Purifier OperationELECTRICAL SHOCK AND HIGH VOLTAGEHAZARDFailure to follow this warning could result in p

Page 11 - WARRANTY

8At the time of air purifier c artridge replacement, if apowderyresidue is noticed on the tips of the points in theionizationarray, proceed to clean t

Page 12 - B --- 0 --- 2

9TROUBLESHOOTINGSAFETY HAZARDFailure to follow this caution may result in personal injuryor equipment damage.The following instructions are for use by